2/3/4 Pole 40-100A Molded Case Residual Current Circuit Breakers RCD RCBO DZ15LE

$ 79.72

Availability: 57 in stock
  • Material: Plastic
  • Protection Properties: Overload Protection
  • Operation Method: On/Off
  • Condition: New
  • Voltage: 220/380V
  • MPN: Does Not Apply
  • Number of Poles: 2
  • Operating Temperature: -5℃ to +40℃
  • Room: Any Room
  • Interruption Type: Air Circuit Breaker (ACB)
  • Timer Control: None
  • Resistance Properties: Corrosion Resistant
  • Electrical Connection: Screw Terminal
  • Number in Pack: 1
  • All returns accepted: Returns Accepted
  • Current Rating: 40-100 A
  • Model: Residual Current Circuit Breaker
  • Application: Commercial
  • Control Style: Switch
  • Suitable For: Wall
  • Return shipping will be paid by: Buyer
  • Country/Region of Manufacture: China
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Brand: Unbranded
  • Item must be returned within: 60 Days
  • Current Type: AC
  • Type: Residual Current Circuit Breaker

    Description

    40 A, 63 A, 100A, 2 Pole, 3 Pole, 4 Pole
    DZ15LE-40/100 Molded Case Residual Current Circuit Breakers Type C MCCB RCD RCBO Air Circuit Breakers Disconnector
    Safety Circuit,
    Overload Protection, Short Circuit Protection, Residual Current Protection
    High-quality materials, environmentally friendly, safe, reliable, and durable, small size, light weight, many varieties and complete specifications. Have complete functions, convenient and flexible installation, easy maintenance, and better cost-effectiveness, allowing you to easily build a safe and exquisite power distribution network.
    DZ15LE series residual current operated circuit breaker is suitable for AC 50Hz, rated voltage of 220V or 380V, and rated current to 100A circuit. It can be used for residual current protection. It can also be used to prevent equipment insulation damage and grounding accident currents. It can be used to protect the circuit from overload and short circuit, and can also be used for infrequent circuit conversion.
    This series of residual current operated circuit breakers are electronic residual current operated circuit breakers, which are mainly composed of a zero sequence current transformer, an electronically controlled leakage release and a circuit breaker with overload and short circuit protection.
    When there is residual current in the protected circuit, as long as the residual current reaches the operating current value, the secondary winding of the zero-sequence transformer will output a signal, and the residual current-operated circuit breaker will operate through the leakage release, thereby cutting off the power supply and reaching Residual current and electric shock protection.
    When an overload or short circuit occurs in the protected circuit, the hydraulic release completes the delay or instantaneous tripping action and causes the residual current operated circuit breaker to operate, thereby cutting off the power supply and achieving overload or short circuit protection.
    Comply with standards: GB/T 14048.2, IEC 60947-2 and CCC certifications.
    Rated Current 40A is DZ15LE-40 model, 63A/100A is DZ15LE-100 model.
    ● Number of Poles: 2 Pole, 3 Pole, 4 Pole
    ● Rated Current ( In ):
    40A, 63A, 100A
    ●Basic specifications and parameters:
    Model
    Current
    Shell Frame
    Rated
    Voltage
    Number of
    Poles
    Rated
    Current
    Rated ultimate short-circuit
    breaking capacity  (Icu)
    Rated residual operating
    current (I

    n)
    Rated residual non-operation
    current (I

    no)
    Arcing
    Distance
    DZ15LE-40
    40A
    220V
    2
    40A
    3kA
    30mA,50mA,75mA,100mA
    15mA,25mA,40mA50mA
    ≤50mm
    380V
    3
    4
    DZ15LE-100
    100A
    220V
    2
    63A,100A
    5kA
    30mA,50mA,75mA100mA,300mA
    15mA,25mA,40mA50mA,150mA
    ≤70mm
    380V
    3
    4
    ● Interruption Type: Air Circuit Breaker (ACB)
    ● Protection Properties: Overload Protection, Short Circuit Protection,Isolation,Residual Current Protection
    ● Shell material: Plastic Flame Retardant Material
    ● Ambient temperature: -5℃ to +40℃, the average should not exceed 35℃ in 24h.
    ● Wiring:
    Rated Current (In)
    Nominal cross-sectional area of copper wire(mm²)
    6A
    1mm²
    10A
    1.5mm²
    16A, 20A
    2.5mm²
    25A
    4mm²
    32A
    6mm²
    40A,50A
    10mm²
    63A
    16mm²
    80A
    25mm²
    100A
    35mm²

    Exact dimensions can also be viewed in the photo gallery.
    ● You can find more products in different material, type, color , sizes, quantity and shapes in our shop! If you have special needs, please contact us, we can customize according to your needs!
    ● Note:
    - Please allow minor errors due to manual measurement. Thank you for your comprehension.
    - Monitors are not calibrated, the element color shown in the photos may differ slightly from the real object. Please take the real one as standard.
    Package included :
    ( According to your choice )
    On Jul-30-21 at 12:01:20 PDT, seller added the following information: